LOGIN/SIGN UP

PRODUCTS 產品總覽 icon

PRODUCTS/VETERINARY MEDICAL DEVICES

"Horien" Extracellular Membrane
Number:SIS

"Horien" Extracellular Membrane

15×20mm

Taiwan: TFDA No. 005701
Thailand: ThaiFDA No. 69-2-1-2-0005937

• Origin: From traceable porcine small intestine
• Technology: Patented decellularization, preserving intact structure/properties
• Components: Collagen, glycosaminoglycan, fibroblast growth factor
• Indication: Guided bone/tissue regeneration surgeries
• Safety: No chemical cross-linking, rigorous quality control
3 sizes:
15x20 mm
20x30 mm
30x40 mm
Login as a licensed physician to purchase LOGIN
  • Description
  • Instructions
  • FAQ

“Horien” Extracellular Membrane

Ensure that you have read, understood, and will carefully follow these instructions before use.

Product Description

“HORIEN” Extracellular Membrane is an extracellular membrane derived from Small Intestinal Submucosa (SIS) of porcine with quality control and using a decellularization process that retains the natural composition of matrix molecules such as collagen, glycosaminoglycan, and growth factors (bFGF). After hydrated, the product remains in the site and will not be disrupted by the closure of the surgical site. If desired, it can be fixed with a suture. The product is virally inactivated and terminally sterilized.
 

Intended Use

“HORIEN” Extracellular Membrane is specially designed for guided tissue regeneration and guided bone regeneration procedures. It is intended for healing periodontal defects, gingival augmentation, maintaining and enhancing alveolar ridges, and preventing migration of graft material.
 

Composition

“HORIEN” Extracellular Membrane is an extracellular membrane derived from Small Intestinal Submucosa (SIS) of porcine. SIS is obtained from qualified animal production facilities and using a decellularization process that retains the natural composition of matrix molecules such as collagen, glycosaminoglycan, fibroblast growth factor.
 

Properties

“HORIEN” Extracellular Membrane adapts to the dimensions of the surgical site once hydrated. After hydration in the site, the material remains in place and is not disrupted by the closure of the surgical site. If desired, “HORIEN” Extracellular Membrane can be fixed with a suture.
 

Safety

“HORIEN” Extracellular Membrane is virally inactivated, terminally sterilized, and subject to a rigorous quality control.

 Contraindications 
he device is derived from a porcine source and should not be used for patients with known sensitivity to porcine material.

 Potential Complications 
Possible complications associated with any periodontal surgery include thermal sensitivity, gingival recession, tissue necrosis, resorption or ankylosis of the treated root, some loss of crestal bone height, gingival dehiscence or fenestration, or abscess formation, pain, swelling, inflammation, infection, gingival irregularities, and complications associated with the use of anesthesia.

 Precautions/ Warnings 

  1. Single use only.
  2. Do not re-sterilize. Discard all open and unused portions.
  3. The device is provided sterile. Do not use if the package seal is broken.
  4. The device is not recommended for use in an infected surgical site.
  5. Do not rehydrate in saline above 37℃.
  6. Do not suture the device until rehydration is complete.

Suggested Instructions for Use

Caution: Handle sheets using aseptic technique.
  1. Prepare the surgical site using standard surgical techniques.
  2. Oversize the device on the defect. Using aseptic technique, trim “HORIEN” Extracellular Membrane to fit the size of the defect well. In addition, provide overlap on each side to stabilize the membrane.
  3. Lack of oversizing the device may result in migration of the device, leading to device failure.
  4. For ease of handling, apply “HORIEN” Extracellular Membrane by placing it in a dry state into the surgical site. Alternatively, the sheet may be rehydrated by placing in the sterile saline, patient’s blood, or other isotonic solution prior to applying to the surgical site.
  5. To minimize bacterial contamination, limit salivary and other contamination to “HORIEN” Extracellular Membrane and the surgical site.
  6. Follow standard surgical procedure in suturing the mucoperiosteal flap over “HORIEN” Extracellular Membrane, ensuring that the device lays flat and does not fold over on itself. Perforation of the device during implantation may result in a device failure.
  7. Discard any unused portions of the device following standard technique for disposal of medical waste.
     

Post-Operative Care

  1. The patient should be monitored closely.
  2. Standard precautions should be taken to minimize oral bacteria exposure.
  3. Precautions should be taken to minimize mechanical disturbance of the membrane.
  4. “HORIEN” Extracellular Membrane is bioresorbable by the body tissues and does not need to be removed.
  5. In the event that membrane removal is necessary, curettage may be required.
     

Storage

The device should be stored in a clean, dry site at room temperature.
 

Sterilization

The device has been sterilized with γ-radiation.
 

Production Specification

1 pc per pack



 
BACK TO LIST